Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.8732915
- Product Categories
- Friendly Links
- home > Supply > Supply, Cixi City, water purifiers, pure water machines, pipeline machines, water dispensers, stainless steel ultrafiltration machine
Supply, Cixi City, water purifiers, pure water machines, pipeline machines, water dispensers, stainless steel ultrafiltration machine
Information Name: | Supply, Cixi City, water purifiers, pure water machines, pipeline machines, water dispensers, stainless steel ultrafiltration machine |
Published: | 2012-03-17 |
Validity: | 900 |
Specifications: | 410 * 390 * 490 |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | Muze The Muze water treatment system is a world-renowned water treatment system management operator. Committed to the world's most advanced water treatment technology and services to spread to areas for improvement for each water quality in the world. Provide customers with reliable and economical water treatment solutions. 2, Muze Muze, Cixi City Electric Technology Co., Ltd. Muze water treatment system in mainland China is the only authorized manufacturer, main products-in-one drink straight, pipeline machines, consumer and commercial reverse osmosis water purifier, water softener and other products, product development, manufacturing, spare parts supply, marketing, international trade, tracking service as one of modern high-tech enterprises. Since the inception of the enterprise, the company all up and down adhering to the "health, environmental protection," business philosophy, adhere to market-oriented, customer-centric, and talent as a fundamental principle to develop a wide range of water appliances. The products are exported to Europe, America, Southeast Asia and other countries and regions. With the rapid economic development, water pollution is more serious, and seriously affect the health of the people. Drinking water pollution has become our responsibility. We always adhere to the specialization, scale, standardization of the development strategy, the "little bit" from the start, and dedication to the quality of water appliances and programs really solve people's drinking water and pollution problems for the benefit of the people of the world. 3, the corporate culture Company vision: first-class brand, make healthy, socially responsible enterprises. Company mission: to consumers, providing high quality products and services; employees, create a harmonious working atmosphere of mutual respect; business partners, to provide a fair and reasonable, mutually beneficial cooperation platform. Core values: 1, which insists on our part, be honest. Commitment to integrity, says it will do. 3, part of a team to create value. 4, the pursuit of quality and customer satisfaction. 5, continuous learning and beyond. Installation and commissioning A selected installation location: directly placed under the kitchen can be installed. kitchen (water purifier) b-mount installation with expansion screws will be water purifier installed on the walls of selected location Two. Install water tees and water ball valve: (a) turn off water main valve, (b) Remove the tap, c. water three common raw material belt wrapped around 10 laps, installed in the water pipe, small ball valve (d) water to raw material belt wrapped around 10 laps or so, installed in the water three links on the side of the hole. (e) to install the faucet at the other end of the water three links, (f), open the tap valve, check the water three links and small ball connected at the inlet seal is good, (g) PE pipe section connected to the water a small valve on the other end of the water purifier inlet connected. 3 Install the faucet (a) the selected installation location of the gooseneck faucet, gooseneck faucet rotation around both the sink inside and outside, easy to use. Drilling in the selected location. (b) the gooseneck faucet in the location of drilling (note the order of installation of the gooseneck kit) After installation, the leading left and right rotation sure to install a solid can be. c Special Note: The nylon ball ring is not lost the drain installation. All levels of filter flushing: a pre-carbon filter activated carbon filter before the water-side to pull out from the quick connector, PE pipe is temporarily connected to a floor drain or other containers. Turn the machine power and water, rinse, and shake the pre-carbon filter filter, repeatedly switching power supply several times, until there is no black water discharge, turn off the power to filter fitted back into place. (b) carbide and activated carbon post-rinse method with pre-activated carbon wash. (c) reverse osmosis (RO) membrane washing will correct a good connection of the various interfaces of the membrane filter, washing its concentrated outlet PE pipe directly connected (without wastewater), the rinse water direct discharge of reverse osmosis (RO) until protective solution completely rinse (about 10 minutes), then the waste pipe and waste connections. (5) check the debug (a) Close the ball valve of the pressure barrel, open the faucet and the water inlet valve, turn on the power, water purification machines automatically begin to enter the wash, then rinse and other bright, wastewater wastewater discharge pipe, washing automatically after 8 seconds to enter The state of water, wash lights off, the system ice lantern light, the pure water will not flow into the pressure barrel directly through the various filter outflow from the faucet. The b.10 minute open the pressure barrels ball valve. Turn off the faucet, clean water flow into the pressure barrel, the water is full of water until the pressure bucket of water full of clean water will automatically shut down, lights go out. Water full of lights. (c) full of water shutdown test, to make pressure barrel full of water, take a long time, in case the water temperature is 25, takes about 50 minutes or so, in order to quickly confirm that the water purifier is normal, for 10 minutes in the water purifier Close pressure barrels ball valve, closed pipe pressure will naturally increase, more 10 seconds until the value of high-voltage switching, high voltage switch is turned off, the booster pump to stop working, this time full of water lights. And then open the faucet water pressure relief, high-pressure switch reset, the booster pump to restart the system water, and so forth 3-5 times to check the booster pump can work to confirm the normal pressure barrels, open the ball valve to allow the system to normal job. (d) lack of water shutdown test, close the water inlet valve to simulate the system dry state, the low pressure switch disconnected, Booster pump to stop work. (e) pipeline inspection, in the process of trial operation, check the parts, components, whether the joints of water seepage, leaks, loose. (f) sorting, cover water purifier surface cover, will enter the outlet pipe, waste pipe finishing and fixed, clean up the site. (g) to open the faucet direct access to fresh pure water. 6 Notes (a) initial installation, not to drink pure water obtained, it should be let go from the faucet for flushing lines and activated carbon. (b) out of the water pipeline to connect Do not bend, so as not to affect the water flux and water protection machine can not work properly. (c) the installation should be combined with the site environment and the user's requirements, give full consideration to the convenience of use and maintenance fittings and piping (d) After installation, check whether the water seepage, leaks. e water pressure test, the first pre-installation check the water pressure, water pressure is lower than 0.05MPa or higher than 0.4MPa, you should install a booster pump or vacuum pump to the water pressure was maintained in 0.05MPa-0.4MPa to make clean water machine water pressure at 0.2MPa-0.3MPa Electrical schematic Transformers 2 low pressure switch high pressure switch four booster pump inlet valve rinse solenoid valve Transformers 2 low pressure switch high pressure switch four booster pump inlet valve rinse solenoid valve 5, product troubleshooting ◎ high-pressure pump does not start, can not be made of water ① check whether the power outage, the plug is plugged in ② Check the low pressure switch failure, the power does not ③ Check the pump and transformer short circuit, or the whole line connection is incorrect ④ Check the high pressure switch or water level controller (the vertical ice heat engine) failure, unable to reset ⑤ Check whether the computer box failure (referring to the microcomputer type) ◎ high-pressure pump to work properly, but you can not make water (1) high-pressure pump voltage ② inlet valve open can not water (concentration of pure water no) ③ pre-filter blockage (the concentration of pure water had no or very small concentration of water) ④ Check Valve failure (there is wastewater water) ⑤ automatic rinse solenoid valve failure can not be effectively closed (has been in the flush state) ⑥ computer box failure can not close the recoil solenoid valve (has been in the flush state) ⑦ RO membrane clogging ◎ high-pressure pump without stopping the machine (1) high-pressure pump pressure is not enough to achieve the high pressure setting of pressure ② check valve blockage, no pure water ③ high voltage switch failure can not jump ◎ high-pressure pump shut down, but wastewater is kept ① inlet valve failure can not be effective without water ② computer box failure, can not close the inlet valve (refer to the microcomputer type) ③ check valve relief (concentrated water flow is small) ◎ full of water, the machine repeatedly jump ① Check valve relief ② high-pressure switch or level switch (refer to vertical ice heat engine) failure (3) pure water piping system pressure relief phenomenon The ◎ pressure full bucket of water, pure water can not outflow ① pressure barrel relief bucket of water (inflated to just discharge date, about 0.3MPa, according to the barometer added pressure to the 0.04-0.08MPa) ② Rear activated carbon blockage ◎ pure water flow insufficient ① pre-filter clogging Lack of (2) high-pressure pump pressure ③ RO membrane clogging The ④ rinse solenoid valve can not be closed The ⑤ rear activated carbon blockage ⑥ Pressure Tanks Pressure or leaky bladder Is ◎ pipeline interface near the leaking? ◆ Check the PE pipe head is cut flat Tube plugs ◆ check whether the plug in place. ◆ check the screw to take are tightened. ◎ Water running in the abnormal noise is the reason? ◆ Check whether the check valve failure or aging ◆ check whether the high-pressure pump quality problems ◆ the original low water pressure, air pump charge ◎ Water Nissan water fail to meet requirements is the reason? ◆ check whether the calculation is wrong ◆ Check the pump pressure is in place (0.6Mpa) ◆ Check the rinse solenoid valve is closed lax ◆ Check the water temperature is too low ◎ thick pipes dense water discharge, the system of pure water and tap water TDS, and why? May occur because: ◆ may occur after the products just installed a large range to remove the water machine, new installation. May have been wrong pipes directly to the high-pressure pump and RO membrane membrane between the shell-activated carbon at the three links, so that high Pump the water directly into the storage tank. Approach: ◆ the right for access ◎ machine does not work is the reason? May occur because: ◆ check whether the power outage, plug into is solid. ◆ whether the loss or failure of the check the low pressure switch wiring plug to the power contacts can not return. ◆ Check the terminals of the cable is off. ◆ check the water pressure is too low to cause the low pressure switch does not work. Approach: ◆ connected to the shedding of plug ◆ replace the low pressure switch ◆ cable off the fitted ◎ system out of pure bad taste or odor, why? ◆ Check the RO membrane shell of pure water and concentrated water-side of the partition or cracks. |
Admin>>>
You are the 8859 visitor
Copyright © GuangDong ICP No. 10089450, The name of Cixi City Electric Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 8859 visitor
Copyright © GuangDong ICP No. 10089450, The name of Cixi City Electric Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility